Technical Elements Documentation
    Preparing search index...

    Variable EDGReliabilityAnalysisExampleConst

    EDGReliabilityAnalysisExample: {
        additionalMetadata: {
            limitations: readonly [
                "Analysis limited to failure-to-start mode",
                "Common cause failures analyzed separately",
            ];
        };
        data_parameters: readonly [
            {
                basicEventId: "BE-EDG-FS-001";
                description: "Failure rate analysis for EDG-A during power operation";
                failure_mode: {
                    description: "Failure to start on demand signal";
                    type: "FAILURE_TO_START";
                };
                name: "Emergency Diesel Generator Failure Rate";
                parameterType: "FREQUENCY";
                probability_model: LOGNORMAL;
                systemComponentId: "SYS-EDG-A";
                uncertainty: {
                    distribution: LOGNORMAL;
                    parameters: { errorFactor: 3; median: 0.000012 };
                };
                uuid: "a1b2c3d4-e89b-12d3-a456-567890abcdef";
                value: 0.000012;
            },
        ];
        description: "Comprehensive data analysis for EDG reliability parameters";
        name: "Emergency Diesel Generator Reliability Analysis";
        status: "APPROVED";
        type: "data-analysis";
        uuid: "123e4567-e89b-12d3-a456-426614174000";
        version: "1.0.0";
    } = ...

    Example of a complete Data Analysis for EDG reliability

    This example demonstrates how to structure a complete data analysis with parameters, metadata, and assumptions.

    Type declaration

    • ReadonlyadditionalMetadata: {
          limitations: readonly [
              "Analysis limited to failure-to-start mode",
              "Common cause failures analyzed separately",
          ];
      }
    • Readonlydata_parameters: readonly [
          {
              basicEventId: "BE-EDG-FS-001";
              description: "Failure rate analysis for EDG-A during power operation";
              failure_mode: {
                  description: "Failure to start on demand signal";
                  type: "FAILURE_TO_START";
              };
              name: "Emergency Diesel Generator Failure Rate";
              parameterType: "FREQUENCY";
              probability_model: LOGNORMAL;
              systemComponentId: "SYS-EDG-A";
              uncertainty: {
                  distribution: LOGNORMAL;
                  parameters: { errorFactor: 3; median: 0.000012 };
              };
              uuid: "a1b2c3d4-e89b-12d3-a456-567890abcdef";
              value: 0.000012;
          },
      ]
    • Readonlydescription: "Comprehensive data analysis for EDG reliability parameters"
    • Readonlyname: "Emergency Diesel Generator Reliability Analysis"
    • Readonlystatus: "APPROVED"
    • Readonlytype: "data-analysis"
    • Readonlyuuid: "123e4567-e89b-12d3-a456-426614174000"
    • Readonlyversion: "1.0.0"
    // Example of a complete data analysis
    const edgAnalysis = {
    uuid: "123e4567-e89b-12d3-a456-426614174000",
    name: "Emergency Diesel Generator Reliability Analysis",
    type: "data-analysis",
    version: "1.0.0",
    status: "APPROVED",
    description: "Comprehensive data analysis for EDG reliability parameters",
    data_parameters: [
    // Array of parameters would go here
    ],
    additionalMetadata: {
    limitations: [
    "Analysis limited to failure-to-start mode",
    "Common cause failures analyzed separately"
    ]
    }
    };