Variable EBRII_PumpDocumentationExampleConst
EBRII_PumpDocumentationExample: {
modelUncertainty: {
name: "EBR-II Primary Sodium Pump Model Uncertainty Documentation";
reasonableAlternatives: readonly [
{
alternative: "Use of Exponential distribution instead of Lognormal for failure rate modeling";
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
reasonNotSelected: "Lognormal better characterizes the uncertainty in the estimated parameters given the limited data";
},
{
alternative: "Separate parameter estimates for different operational phases";
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
reasonNotSelected: "Insufficient data to support statistically significant separate estimates";
},
];
relatedAssumptions: readonly [
{
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
assumption: "EBR-II primary pump reliability characteristics are representative of modern sodium pump designs";
basis: "Design principles for electromagnetic sodium pumps have not fundamentally changed, though materials and manufacturing have improved";
},
{
applicableParameters: readonly ["PARAM-EBRII-PSP-CCF-001"];
assumption: "Common cause failure mechanisms for sodium pumps are similar to those of light water reactor pumps";
basis: "While fluid properties differ, fundamental CCF mechanisms like design errors, manufacturing defects, and maintenance errors remain similar";
},
];
requirementReference: "DA-E2";
uncertaintySources: readonly [
{
applicableParameters: readonly [
"PARAM-EBRII-PSP-FR-001",
"PARAM-EBRII-PSP-FS-001",
];
impact: "Introduces uncertainty in applicability of parameter estimates to current sodium-cooled fast reactor designs";
source: "Operating environment differences between EBR-II and modern liquid metal reactors";
},
{
applicableParameters: readonly [
"PARAM-EBRII-PSP-FR-001",
"PARAM-EBRII-PSP-FS-001",
"PARAM-EBRII-PSP-CCF-001",
];
impact: "Increases uncertainty in generic data applicability and requires greater reliance on expert judgment";
source: "Limited operational history of sodium pumps in commercial power applications";
},
];
uuid: "e87b2c3d-1234-5678-90ab-cdef01234567";
};
preOperationalAssumptions: {
assumptions: readonly [
{
assumptionId: "ASSUME-EBRII-PSP-001";
basis: "Advancements in materials, manufacturing, and control systems are expected to improve reliability";
description: "Modern electromagnetic pump designs will have equal or better reliability than EBR-II pumps";
impact: "May overestimate failure rates if modern designs prove more reliable";
limitations: readonly [
"May not account for new failure modes introduced by design innovations",
"Limited operational experience with newer pump designs",
];
status: "OPEN";
},
{
assumptionId: "ASSUME-EBRII-PSP-002";
basis: "Modern maintenance technologies and practices have generally improved over time";
description: "Maintenance practices for modern sodium pumps will be at least as effective as those for EBR-II";
impact: "May underestimate maintenance-related failures if modern practices prove less effective";
limitations: readonly [
"Loss of institutional knowledge about sodium pump maintenance",
"Reduced availability of specialized maintenance personnel",
];
status: "IN_PROGRESS";
},
];
name: "EBR-II Primary Sodium Pump Pre-Operational Assumptions";
relatedNote: "DA-N-5";
relatedRequirement: "DA-A6";
supportingDocumentationReferences: readonly [
"EBR-II Operational History Report OHR-1994-001",
"Modern Sodium Pump Design Comparison Study MSPD-2023-001",
];
uuid: "f9876543-21ab-cdef-4321-fedcba098765";
validationPhase: "Early operational testing";
};
processDocumentation: {
basicEventProbabilityModels: readonly [
{
basicEventId: "BE-EBRII-PSP-FR-001";
justification: "Lognormal distribution selected based on industry standard practices for continuous operation components with multiplicative failure mechanisms";
model: "LOGNORMAL";
},
{
basicEventId: "BE-EBRII-PSP-FS-001";
justification: "Beta distribution selected for demand-based failure mode to properly model uncertainty with limited data";
model: "BETA";
},
];
bayesianPriorRationales: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
priorDistribution: "Lognormal(μ=-11.51, σ=1.5)";
rationale: "Prior based on generic liquid metal pump failure rates with wide uncertainty to accommodate limited industry experience";
},
];
ccfProbabilityBasis: readonly [
{
ccfParameterId: "PARAM-EBRII-PSP-CCF-001";
estimationMethod: "Alpha Factor Model with specialized adjustment for liquid metal environment";
mappingJustification: "Alpha factors derived from light water reactor experience adjusted for liquid metal environment based on expert judgment";
},
];
componentGroupingDocumentation: readonly [
{
groupId: "GROUP-EBRII-PUMPS-001";
groupingCriteria: "Primary sodium pumps grouped based on similar design, operational characteristics, and environment";
outlierExclusionJustifications: readonly [
{
alternativeTreatment: "Analyzed as separate component with its own failure parameters";
componentId: "COMP-EBRII-PSP-003";
detailedJustification: "Secondary loop pump operates at lower temperature and has different seal design, resulting in significantly different failure characteristics";
exclusionReason: "Significant design differences and operating conditions";
},
];
outlierIdentificationMethodology: "Statistical hypothesis testing comparing failure rates across similar components with 95% confidence threshold";
supportingAnalyses: readonly [
"EBR-II Pump Similarity Analysis Report PSAR-2022-001",
];
},
];
dataCollectionPeriods: readonly [
{
censoringJustification: "Pre-1980 data excluded due to major design modifications to pump control systems";
endDate: "1994-12-31";
parameterId: "PARAM-EBRII-PSP-FR-001";
startDate: "1980-01-01";
},
];
dataExclusionJustifications: readonly [
{
excludedData: "Three failure events during special testing operations in 1983";
justification: "Events occurred during non-standard operating conditions not representative of normal operation";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
];
genericParameterRationales: readonly [
{
operatingStates: readonly ["POS-STARTUP-200", "POS-SHUTDOWN-300"];
parameterId: "PARAM-EBRII-PSP-FS-001";
rationale: "Generic parameters used for startup and shutdown states due to insufficient plant-specific data for these infrequent operating states";
},
];
genericParameterSources: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
reference: "Section 5.4, with adjustments for liquid metal reactor applications";
source: "NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants";
},
{
parameterId: "PARAM-EBRII-PSP-FS-001";
reference: "LMFR-RDB-2023, Section 4.2.1";
source: "Liquid Metal Fast Breeder Reactor Reliability Database (LMFR-RDB)";
},
];
name: "EBR-II Primary Sodium Pump Data Analysis Documentation";
operatingStateDataJustifications: readonly [
{
justification: "Full power operation provides most representative conditions for primary pump failure rates as pumps operate at design flow rates and temperatures";
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
];
parameterEstimates: readonly [
{
estimate: 0.000012;
parameterId: "PARAM-EBRII-PSP-FR-001";
uncertaintyCharacterization: "Lognormal distribution with 5th percentile 2.5e-6, 95th percentile 5.8e-5, error factor 4.8";
},
{
estimate: 0.0034;
parameterId: "PARAM-EBRII-PSP-FS-001";
uncertaintyCharacterization: "Beta distribution with α=2.5, β=732, 5th percentile 6.7e-4, 95th percentile 8.2e-3";
},
];
plantSpecificDataSources: readonly [
{
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
source: "EBR-II Operational Records 1964-1994";
timePeriod: "1980-1994";
},
];
systemComponentBoundaries: readonly [
{
boundaries: readonly [
"Electromagnetic pump assembly",
"Control circuitry",
"Power supply components",
"Primary flow path components",
];
boundaryDescription: "EBR-II primary sodium pump including motor, pump, shaft, bearings, and seals";
componentId: "COMP-EBRII-PSP-001";
references: readonly [
"EBR-II System Design Description SDD-PCS-001",
"EBR-II Primary Pump Drawing E-12345-001",
];
systemId: "SYS-EBRII-PCS-001";
},
];
uuid: "dd72a844-ff75-4517-86a4-5e4bfc7c0384";
};
} = ...
Type declaration
Readonly
modelUncertainty: {
name: "EBR-II Primary Sodium Pump Model Uncertainty Documentation";
reasonableAlternatives: readonly [
{
alternative: "Use of Exponential distribution instead of Lognormal for failure rate modeling";
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
reasonNotSelected: "Lognormal better characterizes the uncertainty in the estimated parameters given the limited data";
},
{
alternative: "Separate parameter estimates for different operational phases";
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
reasonNotSelected: "Insufficient data to support statistically significant separate estimates";
},
];
relatedAssumptions: readonly [
{
applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];
assumption: "EBR-II primary pump reliability characteristics are representative of modern sodium pump designs";
basis: "Design principles for electromagnetic sodium pumps have not fundamentally changed, though materials and manufacturing have improved";
},
{
applicableParameters: readonly ["PARAM-EBRII-PSP-CCF-001"];
assumption: "Common cause failure mechanisms for sodium pumps are similar to those of light water reactor pumps";
basis: "While fluid properties differ, fundamental CCF mechanisms like design errors, manufacturing defects, and maintenance errors remain similar";
},
];
requirementReference: "DA-E2";
uncertaintySources: readonly [
{
applicableParameters: readonly [
"PARAM-EBRII-PSP-FR-001",
"PARAM-EBRII-PSP-FS-001",
];
impact: "Introduces uncertainty in applicability of parameter estimates to current sodium-cooled fast reactor designs";
source: "Operating environment differences between EBR-II and modern liquid metal reactors";
},
{
applicableParameters: readonly [
"PARAM-EBRII-PSP-FR-001",
"PARAM-EBRII-PSP-FS-001",
"PARAM-EBRII-PSP-CCF-001",
];
impact: "Increases uncertainty in generic data applicability and requires greater reliance on expert judgment";
source: "Limited operational history of sodium pumps in commercial power applications";
},
];
uuid: "e87b2c3d-1234-5678-90ab-cdef01234567";
}
Readonly
preOperationalAssumptions: {
assumptions: readonly [
{
assumptionId: "ASSUME-EBRII-PSP-001";
basis: "Advancements in materials, manufacturing, and control systems are expected to improve reliability";
description: "Modern electromagnetic pump designs will have equal or better reliability than EBR-II pumps";
impact: "May overestimate failure rates if modern designs prove more reliable";
limitations: readonly [
"May not account for new failure modes introduced by design innovations",
"Limited operational experience with newer pump designs",
];
status: "OPEN";
},
{
assumptionId: "ASSUME-EBRII-PSP-002";
basis: "Modern maintenance technologies and practices have generally improved over time";
description: "Maintenance practices for modern sodium pumps will be at least as effective as those for EBR-II";
impact: "May underestimate maintenance-related failures if modern practices prove less effective";
limitations: readonly [
"Loss of institutional knowledge about sodium pump maintenance",
"Reduced availability of specialized maintenance personnel",
];
status: "IN_PROGRESS";
},
];
name: "EBR-II Primary Sodium Pump Pre-Operational Assumptions";
relatedNote: "DA-N-5";
relatedRequirement: "DA-A6";
supportingDocumentationReferences: readonly [
"EBR-II Operational History Report OHR-1994-001",
"Modern Sodium Pump Design Comparison Study MSPD-2023-001",
];
uuid: "f9876543-21ab-cdef-4321-fedcba098765";
validationPhase: "Early operational testing";
}
Readonly
processDocumentation: {
basicEventProbabilityModels: readonly [
{
basicEventId: "BE-EBRII-PSP-FR-001";
justification: "Lognormal distribution selected based on industry standard practices for continuous operation components with multiplicative failure mechanisms";
model: "LOGNORMAL";
},
{
basicEventId: "BE-EBRII-PSP-FS-001";
justification: "Beta distribution selected for demand-based failure mode to properly model uncertainty with limited data";
model: "BETA";
},
];
bayesianPriorRationales: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
priorDistribution: "Lognormal(μ=-11.51, σ=1.5)";
rationale: "Prior based on generic liquid metal pump failure rates with wide uncertainty to accommodate limited industry experience";
},
];
ccfProbabilityBasis: readonly [
{
ccfParameterId: "PARAM-EBRII-PSP-CCF-001";
estimationMethod: "Alpha Factor Model with specialized adjustment for liquid metal environment";
mappingJustification: "Alpha factors derived from light water reactor experience adjusted for liquid metal environment based on expert judgment";
},
];
componentGroupingDocumentation: readonly [
{
groupId: "GROUP-EBRII-PUMPS-001";
groupingCriteria: "Primary sodium pumps grouped based on similar design, operational characteristics, and environment";
outlierExclusionJustifications: readonly [
{
alternativeTreatment: "Analyzed as separate component with its own failure parameters";
componentId: "COMP-EBRII-PSP-003";
detailedJustification: "Secondary loop pump operates at lower temperature and has different seal design, resulting in significantly different failure characteristics";
exclusionReason: "Significant design differences and operating conditions";
},
];
outlierIdentificationMethodology: "Statistical hypothesis testing comparing failure rates across similar components with 95% confidence threshold";
supportingAnalyses: readonly [
"EBR-II Pump Similarity Analysis Report PSAR-2022-001",
];
},
];
dataCollectionPeriods: readonly [
{
censoringJustification: "Pre-1980 data excluded due to major design modifications to pump control systems";
endDate: "1994-12-31";
parameterId: "PARAM-EBRII-PSP-FR-001";
startDate: "1980-01-01";
},
];
dataExclusionJustifications: readonly [
{
excludedData: "Three failure events during special testing operations in 1983";
justification: "Events occurred during non-standard operating conditions not representative of normal operation";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
];
genericParameterRationales: readonly [
{
operatingStates: readonly ["POS-STARTUP-200", "POS-SHUTDOWN-300"];
parameterId: "PARAM-EBRII-PSP-FS-001";
rationale: "Generic parameters used for startup and shutdown states due to insufficient plant-specific data for these infrequent operating states";
},
];
genericParameterSources: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
reference: "Section 5.4, with adjustments for liquid metal reactor applications";
source: "NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants";
},
{
parameterId: "PARAM-EBRII-PSP-FS-001";
reference: "LMFR-RDB-2023, Section 4.2.1";
source: "Liquid Metal Fast Breeder Reactor Reliability Database (LMFR-RDB)";
},
];
name: "EBR-II Primary Sodium Pump Data Analysis Documentation";
operatingStateDataJustifications: readonly [
{
justification: "Full power operation provides most representative conditions for primary pump failure rates as pumps operate at design flow rates and temperatures";
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
];
parameterEstimates: readonly [
{
estimate: 0.000012;
parameterId: "PARAM-EBRII-PSP-FR-001";
uncertaintyCharacterization: "Lognormal distribution with 5th percentile 2.5e-6, 95th percentile 5.8e-5, error factor 4.8";
},
{
estimate: 0.0034;
parameterId: "PARAM-EBRII-PSP-FS-001";
uncertaintyCharacterization: "Beta distribution with α=2.5, β=732, 5th percentile 6.7e-4, 95th percentile 8.2e-3";
},
];
plantSpecificDataSources: readonly [
{
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
source: "EBR-II Operational Records 1964-1994";
timePeriod: "1980-1994";
},
];
systemComponentBoundaries: readonly [
{
boundaries: readonly [
"Electromagnetic pump assembly",
"Control circuitry",
"Power supply components",
"Primary flow path components",
];
boundaryDescription: "EBR-II primary sodium pump including motor, pump, shaft, bearings, and seals";
componentId: "COMP-EBRII-PSP-001";
references: readonly [
"EBR-II System Design Description SDD-PCS-001",
"EBR-II Primary Pump Drawing E-12345-001",
];
systemId: "SYS-EBRII-PCS-001";
},
];
uuid: "dd72a844-ff75-4517-86a4-5e4bfc7c0384";
}
Readonly
basicEventProbabilityModels: readonly [
{
basicEventId: "BE-EBRII-PSP-FR-001";
justification: "Lognormal distribution selected based on industry standard practices for continuous operation components with multiplicative failure mechanisms";
model: "LOGNORMAL";
},
{
basicEventId: "BE-EBRII-PSP-FS-001";
justification: "Beta distribution selected for demand-based failure mode to properly model uncertainty with limited data";
model: "BETA";
},
]
Readonly
bayesianPriorRationales: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
priorDistribution: "Lognormal(μ=-11.51, σ=1.5)";
rationale: "Prior based on generic liquid metal pump failure rates with wide uncertainty to accommodate limited industry experience";
},
]
Readonly
ccfProbabilityBasis: readonly [
{
ccfParameterId: "PARAM-EBRII-PSP-CCF-001";
estimationMethod: "Alpha Factor Model with specialized adjustment for liquid metal environment";
mappingJustification: "Alpha factors derived from light water reactor experience adjusted for liquid metal environment based on expert judgment";
},
]
Readonly
componentGroupingDocumentation: readonly [
{
groupId: "GROUP-EBRII-PUMPS-001";
groupingCriteria: "Primary sodium pumps grouped based on similar design, operational characteristics, and environment";
outlierExclusionJustifications: readonly [
{
alternativeTreatment: "Analyzed as separate component with its own failure parameters";
componentId: "COMP-EBRII-PSP-003";
detailedJustification: "Secondary loop pump operates at lower temperature and has different seal design, resulting in significantly different failure characteristics";
exclusionReason: "Significant design differences and operating conditions";
},
];
outlierIdentificationMethodology: "Statistical hypothesis testing comparing failure rates across similar components with 95% confidence threshold";
supportingAnalyses: readonly [
"EBR-II Pump Similarity Analysis Report PSAR-2022-001",
];
},
]
Readonly
dataCollectionPeriods: readonly [
{
censoringJustification: "Pre-1980 data excluded due to major design modifications to pump control systems";
endDate: "1994-12-31";
parameterId: "PARAM-EBRII-PSP-FR-001";
startDate: "1980-01-01";
},
]
Readonly
dataExclusionJustifications: readonly [
{
excludedData: "Three failure events during special testing operations in 1983";
justification: "Events occurred during non-standard operating conditions not representative of normal operation";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
]
Readonly
genericParameterRationales: readonly [
{
operatingStates: readonly ["POS-STARTUP-200", "POS-SHUTDOWN-300"];
parameterId: "PARAM-EBRII-PSP-FS-001";
rationale: "Generic parameters used for startup and shutdown states due to insufficient plant-specific data for these infrequent operating states";
},
]
Readonly
genericParameterSources: readonly [
{
parameterId: "PARAM-EBRII-PSP-FR-001";
reference: "Section 5.4, with adjustments for liquid metal reactor applications";
source: "NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants";
},
{
parameterId: "PARAM-EBRII-PSP-FS-001";
reference: "LMFR-RDB-2023, Section 4.2.1";
source: "Liquid Metal Fast Breeder Reactor Reliability Database (LMFR-RDB)";
},
]
Readonly
name: "EBR-II Primary Sodium Pump Data Analysis Documentation"
Readonly
operatingStateDataJustifications: readonly [
{
justification: "Full power operation provides most representative conditions for primary pump failure rates as pumps operate at design flow rates and temperatures";
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
},
]
Readonly
parameterEstimates: readonly [
{
estimate: 0.000012;
parameterId: "PARAM-EBRII-PSP-FR-001";
uncertaintyCharacterization: "Lognormal distribution with 5th percentile 2.5e-6, 95th percentile 5.8e-5, error factor 4.8";
},
{
estimate: 0.0034;
parameterId: "PARAM-EBRII-PSP-FS-001";
uncertaintyCharacterization: "Beta distribution with α=2.5, β=732, 5th percentile 6.7e-4, 95th percentile 8.2e-3";
},
]
Readonly
plantSpecificDataSources: readonly [
{
operatingState: "POS-FULL-POWER-100";
parameterId: "PARAM-EBRII-PSP-FR-001";
source: "EBR-II Operational Records 1964-1994";
timePeriod: "1980-1994";
},
]
Readonly
systemComponentBoundaries: readonly [
{
boundaries: readonly [
"Electromagnetic pump assembly",
"Control circuitry",
"Power supply components",
"Primary flow path components",
];
boundaryDescription: "EBR-II primary sodium pump including motor, pump, shaft, bearings, and seals";
componentId: "COMP-EBRII-PSP-001";
references: readonly [
"EBR-II System Design Description SDD-PCS-001",
"EBR-II Primary Pump Drawing E-12345-001",
];
systemId: "SYS-EBRII-PCS-001";
},
]
Readonly
uuid: "dd72a844-ff75-4517-86a4-5e4bfc7c0384"
Example of data analysis documentation for EBR-II primary sodium pump
This example demonstrates how to document data analysis for a liquid metal reactor primary sodium pump, with emphasis on documentation requirements (DA-E) and integration with Systems Analysis.